Breaking News :   Jammu getting its due share of inclusive development under Omar Abdullah-led Government: RL Gupta | National Conference afraid of defeat, avoiding Panchayat Polls in J&K: LoP Sharma | MLA Arvind Gupta inaugurates development works worth Rs 65 lakh in Jammu West | BIS raids jewellery outlet in Amritsar; 95 gold jewellery articles weighing 467.44g seized over Hallmarking violations | Reasi police intensify anti-narcotics drive | Distirct police Reasi inspects fertiliser & chemical shops; directs installation of CCTV cameras | Strong law and order and uninterrupted power supply under Yogi Govt give business a new boost | Show-Cause Notice Issued After Chhattisgarh Woman IPS Officer Fires AK-47 During Dussehra Ritual | India Stands For Peace | Chemicals in Festive Foods: A Dangerous Gamble with Human Health | Basohli Utsav: Celebrating Heritage | Crescent School Shines at Speedball Championship | SJVN is organizing 29th Inter CPSU Carrom Tournament | 72 lakh voters ready, but no poll date: J&K’s Panchayat election mystery | Ladakh Panchayat polls on Nov 21 | Delay in court replies won’t be tolerated : Govt warns officers | Amit Shah slams opposition, says protests will achieve nothing | HC main wing to close in Srinagar Oct 31 | J&K to witness dry weather till October 31 | 250-bed maternity hospital awaits site finalisation in Anantnag: CM Omar | India will support every meaningful effort to bring peace to Ukraine, West Asia: PM Modi | J&K Bank net profit rises 10% to Rs 546 crore in September quarter | Man sets stepmother ablaze | 2 OGWs arrested in Baramulla | Man held for pasting anti-national posters | Back Issues  
 
news details
Heat from data centres can raise temperatures in downwind localities: Study
5/19/2026 10:37:39 PM

Early Times Report

NEW DELHI, May 19: A new study conducted in the US’ hottest city Phoenix suggests that waste heat released from data centres can increase air temperatures in downwind neighbourhoods by as much as 4 degrees Fahrenheit, or 2.2 degrees Celsius.
Waste heat produced by a single data centre can surpass the amount emitted by 40,000 households in the US, according to lead author David Sailor, professor and director of Arizona State University’s school of geographical sciences and urban planning.
Air-cooled condenser arrays — which condense turbine exhaust steam — can discharge air heated to 14-25 degrees Fahrenheit (about 8-14 degrees Celsius) above the surrounding air temperature, creating thermal plumes that move downwind over neighbouring areas, researchers said.
“They’re such a concentrated load of electricity consumption and hence heat emissions that we became concerned about the impact that they could have locally, and also in the downwind neighbourhoods,” Sailor said.
“As we do more measurements under different kinds of atmospheric conditions, I think we’re going to see more significant impacts around data centres,” Sailor said.
The researchers said that while previous studies have used remote sensing data from satellites to estimate the heat impact of data centres historically, the study, published in the Journal of Engineering for Sustainable Buildings and Cities, is the first to directly measure air temperatures downwind and upwind of data centres to record real-time effects of waste heat on surrounding communities.
The team mounted data-logging high-accuracy and fast-response temperature sensors on cars that drove around Phoenix-area data centres and throughout nearby neighbourhoods during June 18-October 25, 2025 Using multiple cars allowed the researchers to simultaneously measure temperatures upwind and downwind of four selected facilities ranging from a 36-megawatt single-building data centre in Mesa to a 169-megawatt colocation campus in Chandler (both are cities in Arizona).
The chosen centres reflected the typical design of “hyperscalers” that house thousands of servers and use primarily air-based cooling systems, the team said.
“Five traverses at four facilities in the Phoenix, Arizona metropolitan area, ranging from a 36 MW (megawatt) single-building data center in Mesa to a 169 MW colocation campus in Chandler, reveal downwind air temperature warming as high as 2.2 degrees Celsius, with average downwind air temperatures 0.7-
0.9 degrees Celsius warmer than corresponding upwind areas,” the authors wrote.
“Thermal signatures were detectable at distances up to 500 m (metres) from facility perimeters,” they said.
Sailor said that contributing to an additional heat island magnitude of even one degree or two degrees can significantly impact lives, especially in places where extreme heat already poses public health risks.
A one-degree boost in air temperature, for example, is enough to drive higher use of air conditioning across entire neighbourhoods. Those air conditioners, in turn, put even more heat into the surroundings, the lead author said.
  Share This News with Your Friends on Social Network  
  Comment on this Story  
 
 
 
Early Times Android App
STOCK UPDATE
 
 
 
 
 
 
 
   
Home About Us Top Stories Local News National News Sports News Opinion Editorial ET Cetra Advertise with Us ET E-paper
 
 
J&K RELATED WEBSITES
J&K Govt. Official website
Jammu Kashmir Tourism
JKTDC
Mata Vaishnodevi Shrine Board
Shri Amarnath Ji Shrine Board
Shri Shiv Khori Shrine Board
UTILITY
Train Enquiry
IRCTC
Matavaishnodevi
BSNL
Jammu Kashmir Bank
State Bank of India
PUBLIC INTEREST
Passport Department
Income Tax Department
JK CAMPA
JK GAD
IT Education
Web Site Design Services
EDUCATION
Jammu University
Jammu University Results
JKBOSE
Kashmir University
IGNOU Jammu Center
SMVDU